6 Wire Rtd
video
6 Wire Rtd

6 Wire Rtd

Grade: A or B class
Wire System: 6-wire Pt100(Duplex type)
Process connection: Thread,flange or none
Wire Connection: PTFE wire leads
Diameter: Specify OD

 

I. Core Parameters

Parameter Category

Core Specifications

Product Name

6-Wire RTD (Resistance Temperature Detector)

Accuracy Class

Class A, Class B

Resistance Type

6-wire duplex Pt100 (Pt1000, Cu50, Cu100 optional)

Measuring Temperature Range

-200℃~500℃

Protection Tube Material

SUS304/316L stainless steel, corrosion-resistant alloy, PTFE sleeve

Protection Tube Outer Diameter

3~8mm (standard: 6mm, 6.35mm, 8mm)

Insertion Length

Customizable on demand

Lead Material

PTFE (temperature resistance up to 230℃)

Connection/Installation Method

Threaded, flanged, no connection/installation

Safety Integrity Level

SIL 2

Explosion-Proof Marking (Flameproof Type)

Ex db IICT1~T6 Gb

II. Product Features

Flexible Wiring Modes: Supports 6-wire duplex type, optional 3-wire simplex type. Single resistance wire type is standard; duplex and triplex types are customizable.

Adaptable Installation Scenarios: Offers three installation methods (no installation, threaded installation, flanged installation) to meet fixing requirements of different working conditions.

Strong Material Weather Resistance: Protection tubes are made of SUS304/316L stainless steel, corrosion-resistant alloy, etc., suitable for complex environments; PTFE leads feature high temperature resistance and corrosion resistance.

High Precision and Stability: Complies with Class A and Class B accuracy standards. The resistance value has a stable functional relationship with temperature, ensuring small measurement error and good long-term stability.

Comprehensive Protection Functions: Supports dustproof, waterproof, and flameproof designs. Optional accessories include waterproof joints, flameproof joints, and embedded display terminal heads.

Safety and Compliance: Certified with SIL 2 functional safety certification, CE certification, and explosion-proof certification, meeting multiple national and international standards such as GB/T and ISO.

III. Related Component Specifications

Component Name

Specification Parameters

Wiring Components

Ceramic terminal blocks, connectors, protective caps with compensation wires, protective caps with metal sleeves, compensation wires; assembled RTDs offer optional connectors and ceramic blocks

Terminal Housing

Waterproof joints, flameproof joints, embedded display terminal heads

Protection Tube

Material: SUS304, 316L, corrosion-resistant alloy, PTFE sleeve; Outer diameter: 3~8mm (standard: 6mm, 6.35mm, 8mm)

Leads

Material: PTFE; Maximum temperature resistance: 230℃

Connector

"U" type connector

Installation Accessories

Movable flanges, threaded connectors (material optional: 1Cr18Ni9Ti, etc.)

IV. Application Scenarios

Suitable for industrial scenarios requiring high-precision temperature measurement and complex working conditions, including but not limited to:

Petrochemical Industry: Temperature monitoring of pipelines and reactors

Power Industry: Temperature detection of power station equipment and power transmission systems

Automobile Manufacturing: Temperature monitoring of production equipment and components in automakers such as BYD

Aerospace: Precision temperature measurement in fields like AVIC, AECC, and China Aerospace

Metallurgical Industry: Temperature monitoring of smelting equipment in enterprises such as China Minmetals and CISRI

Scientific Research Institutions: Temperature data collection in scientific experiments of Tsinghua University, National University of Defense Technology, etc.

Others: Temperature control in industrial production processes of chemical groups, CSIC, etc.

V. Product Advantages

High Measurement Precision: 6-wire design effectively reduces the impact of lead resistance; Class A accuracy meets precision measurement needs with strict error control.

Strong Environmental Adaptability: Features corrosion resistance, high temperature resistance, explosion proof, and waterproof properties, adapting to a wide temperature range of -200℃~500℃ and harsh industrial environments.

High Customization Degree: Customizable parameters include resistance type (Pt100, Pt1000, Cu50, etc.), accuracy class, installation method (flanged/threaded/no installation), protection tube material/size, insertion length, wiring components, and explosion-proof/waterproof functions. Specific requirements should be specified during inquiry.

Strong Safety and Compliance: Certified with multiple international and domestic certifications (SIL 2, CE, explosion-proof, ISO14001, ISO45001, etc.), ensuring safe usage.

Good Long-Term Stability: High-quality materials combined with mature craftsmanship result in minimal resistance drift and long service life.

Wide Compatibility: Compatible with various display instruments and safety instrumented systems (SIF), suitable for different industrial control systems.

VI. Frequently Asked Questions (FAQ)

How to select the wiring mode of 6-wire RTD?

Answer: Follow the principle of "convenience and reliability". Select according to working conditions: waterproof joints for dustproof and waterproof scenarios, flameproof joints for flammable and explosive environments, and embedded display terminal heads for on-site display needs. Assembled RTDs can be equipped with ceramic terminal blocks or connectors; compensation wires are required for long-distance measurement.

How to choose the accuracy class?

Answer: Select Class A for high-precision measurement scenarios (e.g., scientific research, precision manufacturing); choose Class B for conventional industrial production scenarios (e.g., ordinary pipeline and equipment monitoring) to balance precision and cost.

How to determine the protection tube material and outer diameter?

Answer: For corrosive working conditions, select 316L or corrosion-resistant alloy; for conventional working conditions, SUS304 is suitable. The outer diameter should be chosen based on installation space and pressure resistance requirements. Standard options include 6mm, 6.35mm, and 8mm; custom sizes are available for special needs.

Does the product support customization?

Answer: Yes! Customizable parameters include resistance type (Pt100, Pt1000, Cu50, etc.), accuracy class, installation method (flanged/threaded/no installation), protection tube material/size, insertion length, wiring components, and explosion-proof/waterproof functions. Specific requirements should be specified during inquiry.

Are the product certifications complete?

Answer: Yes! The product has obtained SIL 2 functional safety certification, CE (LVD/EMC) certification, explosion-proof certification (GYB23.1907X), intellectual property management system certification (GB/T29490-2013), environmental management system certification (ISO14001:2015), and occupational health and safety management system certification (ISO45001:2018), complying with multiple national and international standards.

What information is required for inquiry?

Answer: Please provide the following information: ① Full product series number (if available); ② Application field (petroleum/chemical/power, etc.); ③ Required temperature range; ④ Fixing or installation type (movable flanged type, threaded type, no fixing type); ⑤ Protection tube material and diameter (if needed, e.g., 1Cr18Ni9Ti, 16mm, etc.); ⑥ Insertion length; ⑦ Accuracy class (Class A/Class B); ⑧ Other special requirements (e.g., explosion proof, custom lead length, etc.).

 

product-978-142

How to choose connection ways: The choice of termination should be convenient and reliable minded. There are ceramic wiring blocks, connectors, protective caps with compensation wires, protective caps with metal sleeves, and compensation wires to choose for wire connection ways. For assemble rtd, there are connection heads and ceramic blocks that could be selected from. The purpose of various terminal enclosures is to meet dustproof, waterproof, flameproof, and other requirements. The choices are water-proof head, flame-proof head and display embed terminal head.

 

Quote requirements

 

Pls inform the following thins when you inquire

1)Full series No, If you have

2) Application Scope (Petroleum industry, Chemical industry, Power Station, etc)

3) Required Temperature Range

4) Fixing or Installation Type (Movable Flange Type, Non Fixing type Thread type)

5) Thermowell Material and Diameter if needed(1Cr18Ni9Ti,16,20)

6) Insert Length

7) Accuracy Class(A or B)

8) Other Special Requirements

 

Product details

 

product-750-750
product-750-750

 

Our Customers

 

product-1173-338

 

Insights into our company

 

product-750-560
product-750-560
product-750-560
product-750-560
product-750-560
product-750-560
product-750-560
product-750-560

 

Insights into our production

 

product-750-1000

Manual Welding

product-750-1000

Automatic Welding

product-750-1000

Insulation Testing

product-750-1000

Laser Marking

product-750-1000

Warehouse Managing

product-750-1000

Thermocouple Assemble

product-750-1000

Vacuum Leak Detection

product-750-1000

Surface Polishing

 

Quality Certifications

 

product-750-1040
product-750-1040
product-750-1040
product-750-1040
product-750-1040
product-750-1040
product-750-1040
product-750-1040

Hot Tags: 6 wire rtd, China 6 wire rtd manufacturers, factory, WRPB 2 Calibrated Thermocouple, S Type Semiconductor Thermocouple, S Type Thermocouple, Armored Rtds, , Tungsten Rhenium Thermocouple Below 1700

Send Inquiry